Digital Multimeter

 

  • Dual display for frequency,AC voltage and Temperature measurements
  • 10 MHz frequency counter and decibel measurement.
  • True RMS AC voltage and current readings
  • RS-232 interface and software for downloading measurements to a PC(model 506 only)
  • 10 memory locations and analog bar graph
  • Time and Stop watch mode with Alarm
  • Min., Max., Avg and Relative mode
  • Capacitance and Inductance measurement
  • Temperature measurement in Centigrade and Fahrenheit
  • Frequency generator, logic probe function and back light
  • Auto power off and "keep on" modes


  • Volts DC
    Ranges(5) : 400 mV to 1000V
    Accuracy : 0.5% Rdg + 2D
    Best Resolution : 0.1 mV
    Maximum Input Volt : 1000V DC
  • Volts AC
    Ranges(5) : 400 mV to 750V
    Accuracy : ±1.5%Rdg +5d(50Hz to 500Hz)
    Best Resolution : 0.1 mV
    Maximum Input Volt : 750V AC RMS
  • DC Current
    Ranges : 400§Ë 400mA, 20A
    Accuracy : ±1%Rdg +2d
    Best Resolution : 0.1 §Ë
    Overload Protection : 0.5A and 20A fuse
  • AC Current
    Ranges : 400§Ë, 400mA, 20A
    Accuracy : ±1.5%Rdg +2d, 50Hz to 100Hz
    Best Resolution : 0.1 §Ë
    Overload Protection : 0.5A and 20A fuse
  • Resistance
    Ranges(6) : 400¥Øto 40M¥Ø
    Accuracy : ±0.5%Rdg +2d
    Best Resolution : 0.1¥Ø
    Maximum Input Volt : 250V DC or RMS
  • Decibel
    Ranges(4)  : -31.6 to +59.71dB
    Maximum Input Volt : 750 AC RMS
    Best Accuracy : ±0.5dB
  • Continuity
    Buzzer will sound at < 100¥Ø
    Display will read  : Short when R < 100¥Ø,   Open when R >100¥Ø
  • Diode
    Open circuit voltage : 3.3V max.
    Test current : 1mA Approx.
    Display will read : Short when V < 0.5V,  Good when V = 0.5V to 1V, Open when V > 1V
  • Frequency
    Ranges(4) : 10KHz to 10 MHz
    Accuracy : ±0.01%Rdg ± 1d
    Best Resolution : 1 Hz
    Sensitivity : 1.5 V rms
  • Temperature
    Sensor Type : K type thermocouple
    Range : -17'C to 1200'C,   0'F to 2000'C
    Display : 'C(main display) and'F(sub display)
    Resolution : 1'C and 1'F
    Accuracy : 3% Rdg + 3d, +10'C to 350'C(0'F to 662'F)
                      5% Rdg + 30, 350'C to 1200'C(662'F to 2000'F)
  • Logic Probe
    TTL Level
    Display will read : Lo when V is < 0.8V,  Hi when V is > 2.0V, when V is 0.8 to 2.0V
  • Capacitance
    Range : 0 to 100§Þ
    Accuracy : ±3% Rdg + 5d
    Resolution : 0.01§Þ
  • Inductance
    Range : 0 to 100H
    Resolution : 0.01H
  • Signal out
    Frequency : 2048Hz, 4096Hz,  8192Hz square wave : Accuracy : ±0.01%
    Output level : 4V P-P Min.
    Output Impedance : 1.5K¥Ø
  • Timer
    Range : 1Second to 10 hours
    Accuracy : 0.2% + 1d
    Resolution : 1second
  • RS 232 Interface(506 only)
    Connector : 9 pin female
    Accuracy : 0.2% + 1d
    Baud Rate : 1200 BPS
  • Size :   8"L x 3.53"W x 1.5"D (199mmx88mmx37mm)
  • Weight :   1 lb
  • Power :   9 V Battery
  • Accessories
    Test leads,  operating manual,  9V battery (installed),  holster,  temperature adapter,
    Type "K" temperature probe,   RS-232 cable and Software(model 506 only)

yellow06_up.gif