- Multifunction Vacuum Fluorescent Dual
Display
- True-RMS Voltage and Current Measurement,
Including AC+DC
- 0.05% DC Current Accuracy for 4-20 mA
Current Loop Service
- Standard RS-232 Interface
- Optional IEEE-488.2 Interface
- Frequency Measurement to 1 MHz
- dB Measurements
- MIN/MAX Mode
- RELATIVE Mode
- COMPARE (Hi/Lo/Pass) for Quick In-Tolerance
Tests
- Closed Case Calibration
- Optional Rack-Mount Kit
|
| Form Factor
|
Benchtop
|
| DC Volts
Minimum Range |
300 mV
|
| DC Volts
Maximum Range |
1000 V
|
| DC Volts
No. of Ranges |
5 QTY
|
| DC Volts
Range Steps |
1/10/100
|
| DC Volts
Minimum Resolution |
1 uV
|
| DC Volts
Maximum Resolution |
1 V
|
| DC Volts
Maximum Reading Rate |
150 pt/sec
|
| DC Volts
Basic 1 yr accuracy |
0.02 %
|
| AC Volts
Minimum Range |
300 mV
|
| AC Volts
Maximum Range |
750 V
|
| AC Volts
No. of Ranges |
5 QTY
|
| AC Volts
Range Steps |
1/10/100
|
| AC Volts
Minimum Frequency |
20 Hz
|
| AC Volts
Maximum Frequency |
100 kHz
|
| AC Volts
Minimum Resolution |
10 uV
|
| AC Volts
Maximum Resolution |
1 V
|
| AC Volts
Maximum Reading Rate |
150 pt/sec
|
| AC Volts
Basic 1 Year Accuracy |
0.2 %
|
| True Rms
(?) |
Yes
|
| Normal Mode
Rejection Ratio |
80 dB
|
| Common mode
Rejection Ratio |
60 dB
|
| DC Current
Minimum Range |
30 mA
|
| DC Current
Maximum Range |
10 A
|
| DC Current
No. of Ranges |
3 QTY
|
| DC Current
Range Steps |
1/10/100
|
| DC Current
Minimum Resolution |
1 uA
|
| DC Current
Maximum Resolution |
100 mA
|
| DC Current
Maximum Reading Rate |
150 pt/sec
|
| DC Current
Basic 1 yr accuracy |
0.05 %
|
| AC Current
Minimum Range |
30 mA
|
| AC Current
Maximum Range |
10 A
|
| AC Current
No. of Ranges |
3 QTY
|
| AC Current
Range Steps |
1/10/100
|
| AC Current
Minimum Resolution |
100 nA
|
| AC Current
Maximum Resolution |
10 mA
|
| AC Current
Maximum Reading Rate |
150 pt/sec
|
| AC Current
Basic 1 Year Accuracy |
0.5 %
|
| Resistance
Minimum Range |
300 Ohm
|
| Resistance
Maximum Range |
300 MOhm
|
| Resistance
Minimum Resolution |
1 mOhm
|
| Resistance
Maximum Resolution |
100 kOhm
|
| Resistance
Maximum Reading Rate |
150 pt/sec
|
| Resistance
Basic 1 yr accuracy |
0.05 %
|
| Minimum
Frequency |
5 Hz
|
| Maximum
Frequency |
1 MHz
|
| Frequency
Accuracy |
0.05 %
|
| User
Interface |
Proprietary
|
| Ports to
Peripheral Devices |
RS232C
|
| CE
Compliance |
Not on file
|
| UL
Compliance |
Not
compliant |
| Safety
Issue |
EN601010-1
|
| Input Power
|
Universal
(Auto Sense and Switch) |
| Width |
216 mm(8.5
in) |
| Height |
930
mm(36.61 in) |
| Length |
28.6
mm(1.12 in) |
| Weight |
2.4 kg(5.29
lb)
|